Get in touch with us

zenon Driver Information

zenon Driver
3S
Codesys Arti NG Treiber
Codesys “New Generation” Soft PLC driver for the Codesys 3S-ARTI (asynchronous Runtime interface) interface. The driver supports direct variable transfer from the Codesys development environment and replaces the Codesys Arti Soft PLC driver.
3S
3S v3 Treiber für PLC Handler
3S v3 drive for communication with CoDeSys v3 based PLCs via PLC Handler. The driver uses the real-time stamping in the hardware. Time synchronization between the PLC and SCADA system is necessary.
ABB
ABB-AC500 Treiber
Driver for communication to ABB-AC500 controllers. The driver supports time sync, integrated engineering and browsing.
ABB
BACnet Treiber Next Generation
This driver allows communication between one or more BACnet-compatible devices (BACnet automation stations) and Runtime via BACnet/IP. This requires that the connected BACnet devices run as servers. Only client functionality is implemented in the driver.
ABB
ABB-COMLI Treiber
Driver for the ABB communication link (COMLI) protocol. COMLI is a serial data transfer system from ABB Automation for communication between control systems and controllers. The driver acts as a master.
ABB
Treiber für ABB 07KT94
Serial driver for ABB 07KT94 controllers
ABB
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
ABB
IEC 61400-25-4 C
IEC 61850 Client driver. The driver supports the IEC 61400-25-4 standard, Annex C, which is based on the ACSI services and data classes of IEC 61850. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
ABB
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
ABB
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Actisense
Treiber für NMEA 2000 Bus
Driver for communication with NMEA 2000 components via the Actisense NGT-1 NMEA 2000 to PC Interface. (www.actisense.com)
All
IEC60870-5-101/104 Slave
The slave driver in IEC 60870-5-101 or IEC 60870-5-104 protocol. The driver is a slave (controlled station / outstation)
All
Applicom IO Feldbuskarte
Driver for Applicom IO cards (card type: direct link)
All
AS-Interface Master Karte
Communication with AS interface slaves via an interface module from Bihl + Wiedemann
All
Beckhoff CX1000, lokale E/A
Driver for local I/O modules of a Beckhoff CX1000 embedded PC. Communication via K-Bus.
All
DNP3 Master Treiber
Master driver for the DNP3 / IEEE Std 1815 (tm) protocol. Implements subset level 1, 2 and 3 (requests and responses). Also supports file transfer and device attributes.
All
DNP3 Outstation Treiber
Outstation driver for the DNP3 / IEEE Std 1815 (tm) protocol. Implements subset level 1,2 and 3 (requests and responses). Also supports file transfer and device attributes.
All
HMS Feldbuskarte
Driver for HMS field bus cards; configuration via the HMS configuration software
All
IEC 61850 Client
The IEC 61850 client driver (master). The driver supports IEC 61850-8-1 communication (mapped to MMS protocol) and the following functionality: - browsing of the data model (logical devices, logical nodes, data objects and data attributes) - reading and writing (via FB) of values - commands - all control models (via FB) - reporting (buffered and unbuffered) - dynamic creation and deletion of data sets for RCBs - file transfer (via FB) *) FB - function blocks IEC61850_*
All
IEC 61850 Server + GOOSE
The IEC 61850 server driver; for Edition 1 and Edition 2 of the standard. The driver supports both server-client communication (via MMS) as well as GOOSE publishing/subscription. The driver supports the following functionality of the IEC 61850 protocol: - Several connections to 850 clients via TCP/IP - browsing of the data model by the client (logical devices, logical nodes, data objects and data attributes) - reading and writing of values - reading and writing of data set values - dynamic creation and deletion of data sets - commands - all control models - reporting (buffered and unbuffered) - file transfer - GOOSE publishing, subscription and supervision
All
Interbus-S Master Karte
Driver for Phoenix Contact Interbus card
All
Brodersen IOTOOLS
--
All
MODBUS Master
Driver for the Modbus master protocol. The connection can be serial or via Ethernet.
All
MODBUS Slave
Driver for the Modbus slave protocol. The connection can be serial or via Ethernet.
All
Hilscher SyconCifX Feldbuskarte
Driver for Hilscher field bus cards. Configuration is via the Hilscher "SYCON.net” configuration software. The configuration file must be exported into SYCON.net as an XML file - and imported into the zenon logic field bus configurator.
All
Hilscher CIF Profibus DP
Driver for Hilscher Profibus DP cards (CIF 30, 40, 50, 60, 104). The driver is the master in the Profibus. Configuration is carried out in the zenon Logic field bus configurator.
All
PROFINET IO RT Controller
Realtime Ethernet driver for communication with PROFINET devices. Supports cyclical E/A communication in accordance with Real Time Class 1 (RTC1). This driver can be operated with a normal Ethernet network interface.
All
Shared Memory für Windows
Driver for ‘super-global variables’ communicates between zenon Logic and/or straton Runtime instances that run on the same PC.
All
SoftNet ProfibusDP Feldbuskarte
Driver for Siemens Profibus master cards
All
Hilscher SYCON Feldbuskarte
Driver for Hilscher field bus cards. Configuration is via the Hilscher "SyCon" configuration software. The configuration is exported to SyCon and imported into the zenon Logic field bus configurator.
All
Hilscher SYCON Feldbuskarte
Driver for Hilscher field bus cards. Configuration is via the Hilscher "SyCon" configuration software. The SyCon configuration file is imported into the zenon Logic field bus configurator.
All
WAGO ThinkIO/IOSystem758
Driver for WAGO I/O System 758 (WAGO IPC) or Kontron ThinkIO with Windows CE 5.0
All
Logic-zu-SCADA RT Verbindung
Direct access to variable values and/or TAG information (value, time stamp, status) of SCADA Runtime. TAGs that are marked with the “externally visible” property can be read in runtime. Process data from the SCADA system is thus directly ready for logical processing.
Allen-Bradley
Allen Bradley RS-Linx Treiber
Supports all connections that are offered by RS Linx (http://www.software.rockwell.com)
Allen-Bradley
Allen Bradley DF1-Treiber
For all Allen Bradley controllers that support DF1. The driver works as half duplex
Allen-Bradley
Allen-Bradley ODVA Treiber
Ethernet/IP driver for communication using Common Industrial Protocol - CIP of the Open DeviceNet Vendor Association (ODVA) to 'Allen-Bradley Control-Logix and Compact-Logix controllers. (Please use the 'AllenBradley-DF1' driver for Micro Logix) The driver supports the direct browsing of variables from the controller, offline browsing of project files (*.L5K), and blockwise communication for all types of data including structures and arrays. www.ab.com
Alstom
IEC 60870-5-101_104
Driver for the IEC 60870-5-101 (serial) and the IEC 60870-5-104 (TCP/IP) protocol. The driver is a master (controlling station)
Areva
IEC 60870-5-101_104
Driver for the IEC 60870-5-101 (serial) and the IEC 60870-5-104 (TCP/IP) protocol. The driver is a master (controlling station)
Areva
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Areva
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Asfinag
SaNORS - Notrufsäulen
SaNORS (standard ASFINAG SOS telephone interface) - driver for the ASfINAG SOS telephones (www.asfinag.net)
Bachmann
Bachmann M1 Treiber
Direct TCP/IP driver for Bachmann M1 controllers (www.bachmann.at)
BACnet
BACnet Treiber Next Generation
This driver allows communication between one or more BACnet-compatible devices (BACnet automation stations) and Runtime via BACnet/IP. This requires that the connected BACnet devices run as servers. Only client functionality is implemented in the driver.
Beckhoff
Beckhoff BC-BK 9000
Driver for Beckhoff BC/BK9000. The driver is based on the TC-ADS interface and uses a protocol optimized for the bus terminals.
Beckhoff
Beckhoff TwinCat NG Treiber
"New Generation” Beckhoff TwinCAT driver for TwinCAT Soft PLC 2.6 or higher. The driver is based on the TC-ADS interface. The driver replaces the Beckhoff TC-ADS and the Beckhoff ADS driver. A conversion wizard is available. TC-ADS software must be installed.
Bernecker + Rainer
BuR TCP-IP
Driver for B+R Burklimat and/or B+R System 2000 controllers. Does not require PVI software, but special handling modules in the PLC that can only be obtained from B+R directly. (www.br-automation.com)
Bernecker + Rainer
BuR Transpond. Reader 4102/4150
Driver for Bernecker & Rainer RFID transponder reader 4102/4150 (BuR model number: 5E9000.29) with USB interface.
Bernecker + Rainer
BuR-PVI Treiber NG
Current Bernecker & Rainer driver based on the PVI - interface software from Bernecker & Rainer. Variables can be imported both online and offline by the B&R-OPC interface file (opcs). The communication parameters are saved to the variables directly. The driver supports spontaneous communication with hysteresis. (www.br-automation.com)
Bernecker + Rainer
Mininet-Treiber
Mininet master driver for B+R controllers (www.br-automation.com)
Biffi-Tyco Flow Control
Biffi DCM Master
Driver to connect a redundant Biffi DCM master station. (www.biffi.it)
Bosch Rexroth
3S v3 Treiber für PLC Handler
3S v3 drive for communication with CoDeSys v3 based PLCs via PLC Handler. The driver uses the real-time stamping in the hardware. Time synchronization between the PLC and SCADA system is necessary.
Brodersen
Passiver Modbus RTU Treiber
The driver waits for a TCP/IP port until the Brodersen Gateway establishes a GPRS connection. If the connection is established, communication is carried out using Modbus RTU. (www.brodersencontrols.com)
Brodersen
straton / zenonLogic Treiber
Driver for the connection to straton and zenonLogic
Brodersen
straton NG Treiber
Driver for straton / zenonLogic connections. Replaces the straton32 driver. The driver can use several connections at the same time and uses an improved communication design.
Brodersen
System 2000
Driver for Brodersen RTUs (www.brodersencontrols.com)
Brodersen
SYSTEM2000 LOGGING
Driver for Brodersen RTUs with logging mechanisms. Supports the functionality of reading historical (logged) data. (www.brodersencontrols.com)
Brush
Prismic Event Logger Treiber
Driver to receive online logging information from Prismic controllers with integrated event logger/recorder.
Buderus
Buderus32
The driver communicates with connected ECOCAN-BUS modules via the KM471 module. (http://www.heiztechnik.buderus.de)
CAN
Genrischer Treiber für CAN Bus
Driver for generic CAN communication. The driver reads and writes the 8 data bytes of the standard CAN telegram. A Lawicel AB CANUSB adapter is required (www.canusb.com)
CIMON
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
COPA-DATA
Alternative Datenpunkte
Serves to combine two or more source variables into a virtual variable. With the help of a selector variable, a decision is made which serves to combine two or more source variables into a virtual variable. With a help of a selector variable, a decision is made on which source variable is used. A controller can thus be connected via two different drivers. Depending on which driver is the better connection, it then provides values to the control system for the virtual variable.
COPA-DATA
Archiv Treiber
Writes data in RAW format to the hard drive cyclically. (only values, no time stamp, no status information). The data must be opened/further edited with external tools. (tools only available from COPA-DATA as templates)
COPA-DATA
Dateitreiber
Data exchange with third-party programs on file basis. Values are read in from a file and displayed or archived in zenon. Values from zenon can also be written to a file.
COPA-DATA
DDE Client Treiber
Driver to exchange data with DDE-compatible applications. Also supports NET DDE.
COPA-DATA
OPC Client V2-0
Driver for communication with OPC servers.
COPA-DATA
OPC UA Client Treiber
Driver for communication with OPC-UA (Unified Architecture) servers. The driver only supports data access (DA). www.opcfoundation.org
COPA-DATA
--
--
COPA-DATA
Remote Runtime Treiber
Driver for read-only communication with a remote runtime system. Remote runtimes from version 5.50 are supported. No project amendment is required on the remote system.
COPA-DATA
SQL Treiber
The driver is for two-way data exchange with an ODBC-compatible SQL database.
COPA-DATA
straton / zenonLogic Treiber
Driver for the connection to straton and zenonLogic
COPA-DATA
straton NG Treiber
Driver for straton / zenonLogic connections. Replaces the straton32 driver. The driver can use several connections at the same time and uses an improved communication design.
Costronic
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
CTI
CTI Treiber
Driver for CTI, Texas Instruments TI 505 or Simatic 545/555 controllers. The driver supports the protocols CAMP and NITP with packed task codes.
CTI
TI 505 - 545 Treiber
Driver for Texas Instruments TI 505 / 545. Protocols: TBP, NITP, TCP/IP
Daimler
integra Treiber
Driver for communication with Siemens S7 controllers via the integra standard wait interface of Daimler AG
Database
Archiv Treiber
Writes data in RAW format to the hard drive cyclically. (only values, no time stamp, no status information). The data must be opened/further edited with external tools. (tools only available from COPA-DATA as templates)
Database
SQL Treiber
The driver is for two-way data exchange with an ODBC-compatible SQL database.
Dateien
Archiv Treiber
Writes data in RAW format to the hard drive cyclically. (only values, no time stamp, no status information). The data must be opened/further edited with external tools. (tools only available from COPA-DATA as templates)
Dateien
Dateitreiber
Data exchange with third-party programs on file basis. Values are read in from a file and displayed or archived in zenon. Values from zenon can also be written to a file.
Dateien
DDE Client Treiber
Driver to exchange data with DDE-compatible applications. Also supports NET DDE.
DDE
DDE Client Treiber
Driver to exchange data with DDE-compatible applications. Also supports NET DDE.
DNP3
DNP3 third generation Treiber
Connection to DNP3 outstations; replaces the old DNP332 and DNP3_NG drivers. Read the driver help for information about the switch from the DNP332/DNP3_NG driver to the DNP3_TG driver.
Echelon
i-LON 100
Driver for communication with LON nodes via Echelon iLon100 router. (www.echelon.com)
Echelon
LON
Driver for communication with LON nodes.
EIB
EIB-KNX Bus Treiber
Driver for the communication with the European Installation Bus (EIB/KNX). The driver needs Falcon Runtime in runtime.
Elau
Codesys Arti NG Treiber
Codesys “New Generation” Soft PLC driver for the Codesys 3S-ARTI (asynchronous Runtime interface) interface. The driver supports direct variable transfer from the Codesys development environment and replaces the Codesys Arti Soft PLC driver.
Elau
3S v3 Treiber für PLC Handler
3S v3 drive for communication with CoDeSys v3 based PLCs via PLC Handler. The driver uses the real-time stamping in the hardware. Time synchronization between the PLC and SCADA system is necessary.
Energy-/Infrastructure
IEC60870-5-101/104 Slave
The slave driver in IEC 60870-5-101 or IEC 60870-5-104 protocol. The driver is a slave (controlled station / outstation)
Energy-/Infrastructure
DNP3 Master Treiber
Master driver for the DNP3 / IEEE Std 1815 (tm) protocol. Implements subset level 1, 2 and 3 (requests and responses). Also supports file transfer and device attributes.
Energy-/Infrastructure
DNP3 Outstation Treiber
Outstation driver for the DNP3 / IEEE Std 1815 (tm) protocol. Implements subset level 1,2 and 3 (requests and responses). Also supports file transfer and device attributes.
Energy-/Infrastructure
IEC 61850 Client
The IEC 61850 client driver (master). The driver supports IEC 61850-8-1 communication (mapped to MMS protocol) and the following functionality: - browsing of the data model (logical devices, logical nodes, data objects and data attributes) - reading and writing (via FB) of values - commands - all control models (via FB) - reporting (buffered and unbuffered) - dynamic creation and deletion of data sets for RCBs - file transfer (via FB) *) FB - function blocks IEC61850_*
Energy-/Infrastructure
IEC 61850 Server + GOOSE
The IEC 61850 server driver; for Edition 1 and Edition 2 of the standard. The driver supports both server-client communication (via MMS) as well as GOOSE publishing/subscription. The driver supports the following functionality of the IEC 61850 protocol: - Several connections to 850 clients via TCP/IP - browsing of the data model by the client (logical devices, logical nodes, data objects and data attributes) - reading and writing of values - reading and writing of data set values - dynamic creation and deletion of data sets - commands - all control models - reporting (buffered and unbuffered) - file transfer - GOOSE publishing, subscription and supervision
ESA
Treiber für ESA PCI CIB
Driver for ESA Windows CE Terminal with ESA PCI CIB communication card for Windows CE for communication with MPI-compatible controllers.
Esser
Treiber für Esser BMZ 8000
Driver for Esser BMZ 8000 fire alarm system. The driver only supports read access. (http://www.igs-hagen.de/brandzentralen.htm)
Euchner
Euchner Ident
Driver for Euchner Chipkarten Identsystem (www.euchner.de)
FANUC
--
--
Festo
3S v3 Treiber für PLC Handler
3S v3 drive for communication with CoDeSys v3 based PLCs via PLC Handler. The driver uses the real-time stamping in the hardware. Time synchronization between the PLC and SCADA system is necessary.
Festo
Festo EasyIP Multiprog Treiber
EasyIP driver for Festo IPC/FEC, Multiprog programming. (www.festo.com)
Festo
Festo Seriell-CI- FST
Serial/CI driver for Festo FPC/IPC/FEC, FST programming. Uses test system of the FST kernel. (www.festo.com)
Fieldbus Connectivity
Applicom IO Feldbuskarte
Driver for Applicom IO cards (card type: direct link)
Fieldbus Connectivity
HMS Feldbuskarte
Driver for HMS field bus cards; configuration via the HMS configuration software
Fieldbus Connectivity
MODBUS Master
Driver for the Modbus master protocol. The connection can be serial or via Ethernet.
Fieldbus Connectivity
MODBUS Slave
Driver for the Modbus slave protocol. The connection can be serial or via Ethernet.
Fieldbus Connectivity
Hilscher SyconCifX Feldbuskarte
Driver for Hilscher field bus cards. Configuration is via the Hilscher "SYCON.net” configuration software. The configuration file must be exported into SYCON.net as an XML file - and imported into the zenon logic field bus configurator.
Fieldbus Connectivity
Hilscher CIF Profibus DP
Driver for Hilscher Profibus DP cards (CIF 30, 40, 50, 60, 104). The driver is the master in the Profibus. Configuration is carried out in the zenon Logic field bus configurator.
Fieldbus Connectivity
SoftNet ProfibusDP Feldbuskarte
Driver for Siemens Profibus master cards
Fieldbus Connectivity
Hilscher SYCON Feldbuskarte
Driver for Hilscher field bus cards. Configuration is via the Hilscher "SyCon" configuration software. The configuration is exported to SyCon and imported into the zenon Logic field bus configurator.
Fieldbus Connectivity
Hilscher SYCON Feldbuskarte
Driver for Hilscher field bus cards. Configuration is via the Hilscher "SyCon" configuration software. The SyCon configuration file is imported into the zenon Logic field bus configurator.
Files
Archiv Treiber
Writes data in RAW format to the hard drive cyclically. (only values, no time stamp, no status information). The data must be opened/further edited with external tools. (tools only available from COPA-DATA as templates)
Files
Dateitreiber
Data exchange with third-party programs on file basis. Values are read in from a file and displayed or archived in zenon. Values from zenon can also be written to a file.
Files
DDE Client Treiber
Driver to exchange data with DDE-compatible applications. Also supports NET DDE.
Gantner
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
GE Automation&Controls
GE - SRTP Treiber
Communication to GE controllers via the Service Request Transfer Protocol - SRTP. Nearly all GE Automation & Controls devices that are equipped with an Ethernet port support SRTP. (www.geautomation.com)
GE Automation&Controls
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
GE Automation&Controls
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
GE Multilin
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
GE Multilin
IEC 61400-25-4 C
IEC 61850 Client driver. The driver supports the IEC 61400-25-4 standard, Annex C, which is based on the ACSI services and data classes of IEC 61850. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
GE Multilin
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
GE Multilin
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Gossen Metrawatt
Metrawatt Treiber
Driver for the Gossen Metrawatt U160x energy control systems. Energy and measurement data can be queried with the driver.
Hekatron
ISPIP Hekatron BMZ
Implements the Schrack / Seconet ISP-IP protocol to connect to the Hekatron integral fire system control center. The supported ISP-IP version is 3.4.0
Helmholz
3964R-RK512
Driver for 3964R/RK512
Helmholz
Hilscher MPI Treiber
Driver for Hilscher Netlink adapter (MPI -> TCP/IP) or Hilscher CIF-PB cards. There are Netlink adapters from IBH and Helmholz; they are identical. (http://www.hilscher.com)
Helmholz
HMI Treiber
Driver for the Siemens, Helmholz or Vipa MPI->HMI adapter
Helmholz
PC Adapter - Vipa Green Cable
For serial communication via the Siemens PC adapter / Helmholz PC adapter to Siemens and Vipa PLCs with MPI interface. Alternative: Serial communication to Vipa PLCs via the Vipa Green Cable to the Vipa PG interface.
Hilscher
Hilscher CIF Treiber
Generic CIF driver for Hilscher Interbus and Profibus DP cards (www.hilscher.com). The driver can be configured as a master or as a slave and communicates with the bus participants at data level without protocol.
Hilscher
Hilscher MPI Treiber
Driver for Hilscher Netlink adapter (MPI -> TCP/IP) or Hilscher CIF-PB cards. There are Netlink adapters from IBH and Helmholz; they are identical. (http://www.hilscher.com)
Hitachi
Hitachi
COMM-H driver (www.hitachi.com)
Hydrometer
Hydrometer Treiber
The hydrometer driver serves to connect to the IZAR Center of Hydrometer GmbH. Either M-bus devices or hydrometer radio receivers can be connected to the IZAR Center. Devices in radio range can be read using the radio receiver (M-bus receiver 868). (www.hydrometer.de)
IBH
Hilscher MPI Treiber
Driver for Hilscher Netlink adapter (MPI -> TCP/IP) or Hilscher CIF-PB cards. There are Netlink adapters from IBH and Helmholz; they are identical. (http://www.hilscher.com)
IBH
IBH Soft SPS
The driver supports Siemens S5 and S7 compatible Soft PLC from IBH (www.IBHsoftec.de)
ICE
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Idec
Idec
Driver for Idec MicroSmart, OpenNet controller and FC4A-HPC1. (www.idec.com)
IEC
IEC 61499 Treiber
The driver uses a communication protocol developed by COPA-DATA (SSCP) for spontaneous communication using TCP/IP to IEC 61499 controllers. The protocol specification is published in the driver documentation and can be easily implemented on any controller.
IEC
IEC-62056-21 Treiber
Driver to read values from energy counters using Mode C of the IEC 62056-21 specification. The driver only supports read-only communication.
IEC
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
IEC
IEC 61400-25-4 C
IEC 61850 Client driver. The driver supports the IEC 61400-25-4 standard, Annex C, which is based on the ACSI services and data classes of IEC 61850. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
IEC
IEC 60870-5-101_104
Driver for the IEC 60870-5-101 (serial) and the IEC 60870-5-104 (TCP/IP) protocol. The driver is a master (controlling station)
IEC
IEC60870 103
Driver for IEC 60870-5-103 communication; via TCP/IP or serial. The driver is a master (controlling/monitoring station)
Inat
S5 H1
H1 protocol driver for Siemens S5. H1 or "Industrial Ethernet" is the protocol label for the cell network that is based on the 7-shift model of the ISO/OSI standard. (www.siemens.de, www.inat.de, www.vipa.de). The Inat HI protocol stack (PC-H1 driver) is used on the PC.
Inat
S5 TCP-IP
Driver for S5 TCP/IP communication. The driver supports polling (SEND/RECEIVE) and spontaneous communication (FETCH/WRITE). (www.vipa.de, www.siemens.de, www.inat.de, www.process-informatik.de)
Inat
S7-Treiber Softnet
Driver for S7 controllers via MPI / H1 / Profibus DP / TCP/IP. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
Inat
S7 TCP-IP Treiber
Driver for S7 TCP/IP connection using standard network card without additional software. The driver also supports Simatic PDiag error messages. (www.siemens.com).
Industrial Ethernet
PROFINET IO RT Controller
Realtime Ethernet driver for communication with PROFINET devices. Supports cyclical E/A communication in accordance with Real Time Class 1 (RTC1). This driver can be operated with a normal Ethernet network interface.
Interbus
Hilscher CIF Treiber
Generic CIF driver for Hilscher Interbus and Profibus DP cards (www.hilscher.com). The driver can be configured as a master or as a slave and communicates with the bus participants at data level without protocol.
Interbus
CP001 Gateway Treiber
Driver for the Keba / Hilscher CP001 universal bus gateway. Supports communication via Profibus, Interbus etc.
Interbus
Interbus S Treiber
Driver for Interbus S Generation 4, based on Interbus PC cards from Phönix Contact (www.phoenixcontact.com).
Internal driver
Treiber für interne Variablen
Driver for internal variable. Variables can be local or global and can be started with an initial value or the last value (remanence). The driver does not consume any I/Os or TAGs.
Internal driver
Treiber für math. Berechnungen
zenon math driver For numeric and binary operations. The driver does not use any I/Os or TAGs.
Internal driver
Treiber für Simulator-Variablen
zenon simulator driver for simulation and internal variables. Variables can also be stored permanently. The driver does not consume any I/Os or TAGs.
Internal driver
Treiber für System-Variablen
zenon system driver to read internal project information, network information, PC hardware information etc. The driver does not use any I/Os or TAGs.
Jetter
Jetter Treiber
Driver for communication with Jetter PLCs via the serial interface, JetWay, PCPPLC or via the network with UDP or TCP (JetIP/JetSTX) www.jetter.de
JTEKT
--
--
Kaba
Kaba Datenpunktserver Treiber
Connection to the Kaba exos 9300 access management system via a data point server. www.kaba.com
Kalki
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
Kalki
IEC 61400-25-4 C
IEC 61850 Client driver. The driver supports the IEC 61400-25-4 standard, Annex C, which is based on the ACSI services and data classes of IEC 61850. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
Keba
CP001 Gateway Treiber
Driver for the Keba / Hilscher CP001 universal bus gateway. Supports communication via Profibus, Interbus etc.
Keba
Kemro User ID Treiber
Driver to connect to the Kemro User ID USB interface. Data from Keba RFID chips can thus be read. The driver can only be obtained via Keba in conjunction with the hardware. (www.keba.com)
Keba
Ketop Treiber
Driver for the buttons on the KeTop T100 and T50
KEPCO
Kepco KDNP1 Treiber
The KDNP1 driver is for communication with KEPCO's KDNP1 protocol based on the DNP3 standard. The driver is master. At protocol level, serial communication and TCP/IP communication to several outstations is supported
Kieback + Peter
BACnet Treiber Next Generation
This driver allows communication between one or more BACnet-compatible devices (BACnet automation stations) and Runtime via BACnet/IP. This requires that the connected BACnet devices run as servers. Only client functionality is implemented in the driver.
KNX
EIB-KNX Bus Treiber
Driver for the communication with the European Installation Bus (EIB/KNX). The driver needs Falcon Runtime in runtime.
Koyo
KOYO-Sequence Treiber
Driver for Koyo Sequence models (www.koyoele.co.jp/english)
Kuka Robotics
Treiber für KUKA Roboter
The driver communicates directly with the robot controller Cross3KRC to directly read and write robot data
Kuka Robotics
Phoenix Contact Treiber
Direct driver for all Phoenix Contact controllers based on ProConOS. www.phoenixcontact.com
KW-Software
Phoenix Contact Treiber
Direct driver for all Phoenix Contact controllers based on ProConOS. www.phoenixcontact.com
Laetus
VDMA-XML Treiber
Driver to connect smart components in packaging and process machines via the VDMAXML_P protocol, for example: Laetus components. www.vdma.org, www.laetus.com
Lauer
PCS807 Profibus DP
Driver for Lauer PCS807 communication box for communication via ProfibusDP. (www.systeme-lauer.de)
Lauer
Lauer PCS812
Driver for Lauer PCS812 communication box for communication via MPI. (www.systeme-lauer.de)
Lawicel
Genrischer Treiber für CAN Bus
Driver for generic CAN communication. The driver reads and writes the 8 data bytes of the standard CAN telegram. A Lawicel AB CANUSB adapter is required (www.canusb.com)
LON
i-LON 100
Driver for communication with LON nodes via Echelon iLon100 router. (www.echelon.com)
LON
LON
Driver for communication with LON nodes.
LSIS
LS Industrial Systems-XGT
For LS Industrial Systems XGT Series controllers. For input and output, symbolic and direct variables. Supports numeric data types from 1 bit to 8 bytes (eng.lsis.biz).
Mastervolt
MasterBus Treiber
Driver for connection to a MasterBus system via the Mastervolt MasterBus Modbus Interface (www.mastervolt.com)
Matsushita
Panasonic Seriell
Driver for Panasonic (formerly Matsushita) FPx controllers (www.panasonic-electric-works.com). The driver also supports modem connection.
Matsushita
Panasonic TCP-IP
TCP/IP driver for Panasonic (formerly Matsushita) FPx controllers using standard network card. (www.panasonic-electric-works.com)
M-Bus
Standard M-Bus
Driver for the standard M-Bus protocol.
Metrawatt
Metrawatt Treiber
Driver for the Gossen Metrawatt U160x energy control systems. Energy and measurement data can be queried with the driver.
Microsoft
Azure Treiber
Driver for read-only communication with Microsoft Azure Service Bus in the cloud. The data can be written to the MS Azure Service Bus using Azure Gateway and obtained from there again with the driver in another Runtime. Intended for cross-facility communication without TCP/IP port releases.
Mitsubishi
Mitsubishi - Melsec A-Q
Driver for the Mitsubishi A and Q series. (http://www.meau.com)
Mitsubishi
Mitsubishi - Melsec FX
Driver for the Mitsubishi FX series. (http://www.meau.com)
Modbus RTU
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Modbus RTU
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Modbus RTU
Passiver Modbus RTU Treiber
The driver waits for a TCP/IP port until the Brodersen Gateway establishes a GPRS connection. If the connection is established, communication is carried out using Modbus RTU. (www.brodersencontrols.com)
Modicon
Modicon TSX
Connection to Modicon TSX PLC via Unitelway protocol. (www.schneider-electric.de)
Moeller
Codesys Arti NG Treiber
Codesys “New Generation” Soft PLC driver for the Codesys 3S-ARTI (asynchronous Runtime interface) interface. The driver supports direct variable transfer from the Codesys development environment and replaces the Codesys Arti Soft PLC driver.
Moeller
Profibus DP Mastertreiber
Developed for special Moeller Profibus DP participants. Can also communicate with other passive Profibus DP participants. A better alternative: zenonLogic with Profibus DP driver.
Moeller
Moeller PSUNI
Driver for Klöckner+Moeller controllers. (www.moeller.net)
Mondial
Mininet-Treiber
Mininet master driver for B+R controllers (www.br-automation.com)
Mondial
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Mondial
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
MPI
3964R-RK512
Driver for 3964R/RK512
MPI
S7 CE-MPI
Driver for MPI Siemens CE platform (http://www.open-platform-program.com/products/default.asp)
MPI
Hilscher MPI Treiber
Driver for Hilscher Netlink adapter (MPI -> TCP/IP) or Hilscher CIF-PB cards. There are Netlink adapters from IBH and Helmholz; they are identical. (http://www.hilscher.com)
MPI
Treiber für ESA PCI CIB
Driver for ESA Windows CE Terminal with ESA PCI CIB communication card for Windows CE for communication with MPI-compatible controllers.
MPI
HMI Treiber
Driver for the Siemens, Helmholz or Vipa MPI->HMI adapter
MPI
Lauer PCS812
Driver for Lauer PCS812 communication box for communication via MPI. (www.systeme-lauer.de)
MPI
S7-Treiber Softnet
Driver for S7 controllers via MPI / H1 / Profibus DP / TCP/IP. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
MPI
PC Adapter - Vipa Green Cable
For serial communication via the Siemens PC adapter / Helmholz PC adapter to Siemens and Vipa PLCs with MPI interface. Alternative: Serial communication to Vipa PLCs via the Vipa Green Cable to the Vipa PG interface.
NARI
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
NMEA
Treiber für NMEA 2000 Bus
Driver for communication with NMEA 2000 components via the Actisense NGT-1 NMEA 2000 to PC Interface. (www.actisense.com)
NR Electric
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
OEM Device I/O
Beckhoff CX1000, lokale E/A
Driver for local I/O modules of a Beckhoff CX1000 embedded PC. Communication via K-Bus.
OEM Device I/O
WAGO ThinkIO/IOSystem758
Driver for WAGO I/O System 758 (WAGO IPC) or Kontron ThinkIO with Windows CE 5.0
Omron
Omron FINS Treiber
Driver for Omron SYSMAC. FINS = Factory Information Network System (www.europe.omron.com)
Omron
OMRON Treiber
Driver for Omron controllers (www.europe.omron.com)
OPC
OPC Client V2-0
Driver for communication with OPC servers.
OPC
OPC UA Client Treiber
Driver for communication with OPC-UA (Unified Architecture) servers. The driver only supports data access (DA). www.opcfoundation.org
OSAI
OSAI TCP/IP Treiber
Driver for the OSAI Soft PLC/CNC controller based on Windows CE. (www.osai.it)
Other
Shared Memory für Windows
Driver for ‘super-global variables’ communicates between zenon Logic and/or straton Runtime instances that run on the same PC.
Otis
Treiber für Otis Controller
Driver to connect to Otis controller (elevator control). The driver only supports read access. (www.otis.com)
Panasonic
Panasonic Seriell
Driver for Panasonic (formerly Matsushita) FPx controllers (www.panasonic-electric-works.com). The driver also supports modem connection.
Panasonic
Panasonic TCP-IP
TCP/IP driver for Panasonic (formerly Matsushita) FPx controllers using standard network card. (www.panasonic-electric-works.com)
Phoenix Contact
Interbus S Treiber
Driver for Interbus S Generation 4, based on Interbus PC cards from Phönix Contact (www.phoenixcontact.com).
Phoenix Contact
Phoenix Contact Treiber
Direct driver for all Phoenix Contact controllers based on ProConOS. www.phoenixcontact.com
Pilz
PILZ-PSS
Driver for Pilz PSS controllers for ST area; FS area is not supported. (www.pilz.com)
Pozyton
Treiber für Pozyton Zähler
Driver for the reading of meter data from POZYTON meters (http://www.pozyton.com.pl)
Process-Informatik
S5 TCP-IP
Driver for S5 TCP/IP communication. The driver supports polling (SEND/RECEIVE) and spontaneous communication (FETCH/WRITE). (www.vipa.de, www.siemens.de, www.inat.de, www.process-informatik.de)
Process-Informatik
S7-Treiber Softnet
Driver for S7 controllers via MPI / H1 / Profibus DP / TCP/IP. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
Process-Informatik
S7 TCP-IP Treiber
Driver for S7 TCP/IP connection using standard network card without additional software. The driver also supports Simatic PDiag error messages. (www.siemens.com).
Profibus DP
Hilscher CIF Treiber
Generic CIF driver for Hilscher Interbus and Profibus DP cards (www.hilscher.com). The driver can be configured as a master or as a slave and communicates with the bus participants at data level without protocol.
Profibus DP
CP001 Gateway Treiber
Driver for the Keba / Hilscher CP001 universal bus gateway. Supports communication via Profibus, Interbus etc.
Profibus DP
Profibus DP Mastertreiber
Developed for special Moeller Profibus DP participants. Can also communicate with other passive Profibus DP participants. A better alternative: zenonLogic with Profibus DP driver.
Profibus DP
PCS807 Profibus DP
Driver for Lauer PCS807 communication box for communication via ProfibusDP. (www.systeme-lauer.de)
Profibus DP
S7-Treiber Softnet
Driver for S7 controllers via MPI / H1 / Profibus DP / TCP/IP. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
Profibus FMS
FMS mit PC-Karte von Siemens
Profibus FMS driver. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
Reis
Reis Robotics Treiber
Driver for Reis Robotics robots (www.reisrobotics.com)
Rockwell
Allen Bradley RS-Linx Treiber
Supports all connections that are offered by RS Linx (http://www.software.rockwell.com)
Rockwell
Allen Bradley DF1-Treiber
For all Allen Bradley controllers that support DF1. The driver works as half duplex
Rockwell
Allen-Bradley ODVA Treiber
Ethernet/IP driver for communication using Common Industrial Protocol - CIP of the Open DeviceNet Vendor Association (ODVA) to 'Allen-Bradley Control-Logix and Compact-Logix controllers. (Please use the 'AllenBradley-DF1' driver for Micro Logix) The driver supports the direct browsing of variables from the controller, offline browsing of project files (*.L5K), and blockwise communication for all types of data including structures and arrays. www.ab.com
RTK Instruments
RTK9000 Treiber
Driver for the serial connection to an RTK Instruments System 9000TS sequence of events recorder or to a Series 725B combined annunciator and event recorder (www.rtkinstruments.com)
Saia
Saia Directly
Driver for direct SAIA communication via PGU,SBUS, P800 and TCP, but not via modem. No SAIA software required. (www.saia-burgess.com)
Saia
SAIA2ND32 Treiber
Driver for PGU,SBUS, P800, modem, TCP. Whereby it is possible to communicate with one PLC per driver via TCP. (www.saia-burgess.com)
SAT
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
SAT
IEC 61400-25-4 C
IEC 61850 Client driver. The driver supports the IEC 61400-25-4 standard, Annex C, which is based on the ACSI services and data classes of IEC 61850. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
SAT
IEC 60870-5-101_104
Driver for the IEC 60870-5-101 (serial) and the IEC 60870-5-104 (TCP/IP) protocol. The driver is a master (controlling station)
Sauter
3964R-RK512
Driver for 3964R/RK512
SCADA Runtime Connectivity
Logic-zu-SCADA RT Verbindung
Direct access to variable values and/or TAG information (value, time stamp, status) of SCADA Runtime. TAGs that are marked with the “externally visible” property can be read in runtime. Process data from the SCADA system is thus directly ready for logical processing.
Schiele
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Schiele
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Schiele
Schiele S400
Driver for Systron S400
Schleicher
3964R-RK512
Driver for 3964R/RK512
Schneider
3S v3 Treiber für PLC Handler
3S v3 drive for communication with CoDeSys v3 based PLCs via PLC Handler. The driver uses the real-time stamping in the hardware. Time synchronization between the PLC and SCADA system is necessary.
Schneider
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Schneider
Modicon TSX
Connection to Modicon TSX PLC via Unitelway protocol. (www.schneider-electric.de)
Schneider
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Schweitzer Engineering Laboratories
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
Schweitzer Engineering Laboratories
SEL Fast Message Protokoll
Serial driver for all SEL IEDs that support Fast Message Protocol. The driver supports Fast Meter (binary data only) and Fast Operate.
SE Elektronic
BACnet Treiber Next Generation
This driver allows communication between one or more BACnet-compatible devices (BACnet automation stations) and Runtime via BACnet/IP. This requires that the connected BACnet devices run as servers. Only client functionality is implemented in the driver.
SE Elektronic
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
SE Elektronic
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
SEL
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
Sensor-/Actuator Connectivity
AS-Interface Master Karte
Communication with AS interface slaves via an interface module from Bihl + Wiedemann
Sensor-/Actuator Connectivity
Interbus-S Master Karte
Driver for Phoenix Contact Interbus card
Siemens
3964R-RK512
Driver for 3964R/RK512
Siemens
BACnet Treiber Next Generation
This driver allows communication between one or more BACnet-compatible devices (BACnet automation stations) and Runtime via BACnet/IP. This requires that the connected BACnet devices run as servers. Only client functionality is implemented in the driver.
Siemens
S7 CE-MPI
Driver for MPI Siemens CE platform (http://www.open-platform-program.com/products/default.asp)
Siemens
Hilscher MPI Treiber
Driver for Hilscher Netlink adapter (MPI -> TCP/IP) or Hilscher CIF-PB cards. There are Netlink adapters from IBH and Helmholz; they are identical. (http://www.hilscher.com)
Siemens
CTI Treiber
Driver for CTI, Texas Instruments TI 505 or Simatic 545/555 controllers. The driver supports the protocols CAMP and NITP with packed task codes.
Siemens
Treiber für ESA PCI CIB
Driver for ESA Windows CE Terminal with ESA PCI CIB communication card for Windows CE for communication with MPI-compatible controllers.
Siemens
FMS mit PC-Karte von Siemens
Profibus FMS driver. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
Siemens
HMI Treiber
Driver for the Siemens, Helmholz or Vipa MPI->HMI adapter
Siemens
IEC-62056-21 Treiber
Driver to read values from energy counters using Mode C of the IEC 62056-21 specification. The driver only supports read-only communication.
Siemens
IEC 61400-25-4 C
IEC 61850 Client driver. The driver supports the IEC 61400-25-4 standard, Annex C, which is based on the ACSI services and data classes of IEC 61850. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
Siemens
IEC 60870-5-101_104
Driver for the IEC 60870-5-101 (serial) and the IEC 60870-5-104 (TCP/IP) protocol. The driver is a master (controlling station)
Siemens
integra Treiber
Driver for communication with Siemens S7 controllers via the integra standard wait interface of Daimler AG
Siemens
PCS807 Profibus DP
Driver for Lauer PCS807 communication box for communication via ProfibusDP. (www.systeme-lauer.de)
Siemens
Lauer PCS812
Driver for Lauer PCS812 communication box for communication via MPI. (www.systeme-lauer.de)
Siemens
S5 H1
H1 protocol driver for Siemens S5. H1 or "Industrial Ethernet" is the protocol label for the cell network that is based on the 7-shift model of the ISO/OSI standard. (www.siemens.de, www.inat.de, www.vipa.de). The Inat HI protocol stack (PC-H1 driver) is used on the PC.
Siemens
Siemens S5 PG Treiber
Driver for the programming interface of the Siemens Simatic S5 with AS 511 protocol. (www.siemens.com)
Siemens
S5 TCP-IP
Driver for S5 TCP/IP communication. The driver supports polling (SEND/RECEIVE) and spontaneous communication (FETCH/WRITE). (www.vipa.de, www.siemens.de, www.inat.de, www.process-informatik.de)
Siemens
S7 Treiber für S7-200
Connection to Siemens S7 200 controllers
Siemens
S7-Treiber Softnet
Driver for S7 controllers via MPI / H1 / Profibus DP / TCP/IP. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
Siemens
Siclimat X DCOS
Driver for communication with Siemens Siclimat X building services control system
Siemens
PC Adapter - Vipa Green Cable
For serial communication via the Siemens PC adapter / Helmholz PC adapter to Siemens and Vipa PLCs with MPI interface. Alternative: Serial communication to Vipa PLCs via the Vipa Green Cable to the Vipa PG interface.
Siemens
S7 Spont
Spontaneous driver for Siemens S7 TCP/IP. The driver needs a handling module in the PLC.
Siemens
S7 TCP-IP Treiber
Driver for S7 TCP/IP connection using standard network card without additional software. The driver also supports Simatic PDiag error messages. (www.siemens.com).
Siemens
S7-Treiber für S7-1200/1500
S7 driver for Series S7-1200 and S7-1500 controllers. The driver supports access to the optimized modules. Supported TIA portal versions: TIA V11 up to SP2 update 5; TIA V12 up to SP1 update 4; TIA V13 up to SP1 update 9; TIA V14 (as at Jan 2017). www.siemens.com
Siemens
Siemens Sigmasys Treiber
Driver for the Siemens Sigmasys fire alarm control. Spontaneous slave driver based on the GMA manager (Destination Management System)
Siemens
Simotion Treiber
Driver for Simotion D4x5 connection using standard network card without additional software. Offline variable import of Siemens scout file possible. (www.siemens.com)
Siemens
TI 505 - 545 Treiber
Driver for Texas Instruments TI 505 / 545. Protocols: TBP, NITP, TCP/IP
Sigmatek
SIGMATEK
Connection to Sigmatek products (www.sigmatek.at)
Sigmatek
Sigmatek Lasal Treiber
Connection to all Sigmatek controllers that can be configured with the LASAL configuration software.
Sinthesi
PICnet Treiber
Driver for Sinthesi PICnet PLCs. (www.sinthesi.com) communication using SAPP (Sinthesi Asynchronous Packet Protocol)
SNMP
SNMP Treiber
Driver for communication with SNMP-compatible devices via SNMP v1 and v2.
SNMP
SNMP Treiber New Generation
Driver for communication with SNMP-compatible devices via SNMP v1, v2 and v3.
Sprecher Automation
IEC 61850 Treiber
IEC 61850 client driver. The communication between driver and the controllers (IED - Intelligent Electronic Devices) is based on the IEC 61850 protocol. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
Sprecher Automation
IEC 61400-25-4 C
IEC 61850 Client driver. The driver supports the IEC 61400-25-4 standard, Annex C, which is based on the ACSI services and data classes of IEC 61850. Communication - mapped to MMS protocol, in accordance with the guidelines of the IEC 61850-8-1 standard - is effected via TCP/IP. The driver acts as a client (master) in the communication.
Sprecher Automation
IEC 60870-5-101_104
Driver for the IEC 60870-5-101 (serial) and the IEC 60870-5-104 (TCP/IP) protocol. The driver is a master (controlling station)
SQL
Variablenwerte in SQL schreiben
The driver writes the values of the selected variables in a table of the SQL database which is addresses via an ODBC driver.
SQL
SQL Treiber
The driver is for two-way data exchange with an ODBC-compatible SQL database.
straton
OPC UA Client Treiber
Driver for communication with OPC-UA (Unified Architecture) servers. The driver only supports data access (DA). www.opcfoundation.org
straton
straton / zenonLogic Treiber
Driver for the connection to straton and zenonLogic
straton
straton NG Treiber
Driver for straton / zenonLogic connections. Replaces the straton32 driver. The driver can use several connections at the same time and uses an improved communication design.
Telemecanique
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Telemecanique
Modicon TSX
Connection to Modicon TSX PLC via Unitelway protocol. (www.schneider-electric.de)
Telemecanique
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Texas Instruments
CTI Treiber
Driver for CTI, Texas Instruments TI 505 or Simatic 545/555 controllers. The driver supports the protocols CAMP and NITP with packed task codes.
Texas Instruments
TI 505 - 545 Treiber
Driver for Texas Instruments TI 505 / 545. Protocols: TBP, NITP, TCP/IP
TOYODA
--
--
Trend
BACnet Treiber Next Generation
This driver allows communication between one or more BACnet-compatible devices (BACnet automation stations) and Runtime via BACnet/IP. This requires that the connected BACnet devices run as servers. Only client functionality is implemented in the driver.
Trend
Trend Treiber
Direct, serial driver to Trend controllers. The driver does not need any additional software. (www.trendcontrols.com)
Trend
Trend NG Treiber
The driver has the same range of functions as the Trend32 driver, but it is based on the Trend TCC suite. It can thus not only communicate in serial, but also via all communication types (such as TCP/IP, modem) that the TCC suite supports. (www.trendcontrols.com)
VDMA
VDMA-XML Treiber
Driver to connect smart components in packaging and process machines via the VDMAXML_P protocol, for example: Laetus components. www.vdma.org, www.laetus.com
Vipa
Treiber für ESA PCI CIB
Driver for ESA Windows CE Terminal with ESA PCI CIB communication card for Windows CE for communication with MPI-compatible controllers.
Vipa
HMI Treiber
Driver for the Siemens, Helmholz or Vipa MPI->HMI adapter
Vipa
Lauer PCS812
Driver for Lauer PCS812 communication box for communication via MPI. (www.systeme-lauer.de)
Vipa
S5 H1
H1 protocol driver for Siemens S5. H1 or "Industrial Ethernet" is the protocol label for the cell network that is based on the 7-shift model of the ISO/OSI standard. (www.siemens.de, www.inat.de, www.vipa.de). The Inat HI protocol stack (PC-H1 driver) is used on the PC.
Vipa
S5 TCP-IP
Driver for S5 TCP/IP communication. The driver supports polling (SEND/RECEIVE) and spontaneous communication (FETCH/WRITE). (www.vipa.de, www.siemens.de, www.inat.de, www.process-informatik.de)
Vipa
S7-Treiber Softnet
Driver for S7 controllers via MPI / H1 / Profibus DP / TCP/IP. Based on Siemens SIMATIC NET (Softnet) software. (www.siemens.com)
Vipa
PC Adapter - Vipa Green Cable
For serial communication via the Siemens PC adapter / Helmholz PC adapter to Siemens and Vipa PLCs with MPI interface. Alternative: Serial communication to Vipa PLCs via the Vipa Green Cable to the Vipa PG interface.
Vipa
S7 TCP-IP Treiber
Driver for S7 TCP/IP connection using standard network card without additional software. The driver also supports Simatic PDiag error messages. (www.siemens.com).
Volkswagen
Intern Treiber mit Zeitstempel
Internal driver that returns each set value as an actual value with unchanged value and new time stamp. Status bits for cause of transmission are also amended. It is thus ensured that, when writing a set value with the same value and same time stamp (VBA/VSTA), the value is detected as amended and forwarded.
Wago
3S v3 Treiber für PLC Handler
3S v3 drive for communication with CoDeSys v3 based PLCs via PLC Handler. The driver uses the real-time stamping in the hardware. Time synchronization between the PLC and SCADA system is necessary.
Wago
Modbus Energy Treiber
Open Modbus TCP/IP driver with the following differences from the standard Modbus driver: - TCP/IP channel bundling: Improved communication to gateways - only read and write holding register - only Open Modbus TCP protocol - sequence of events for AREVA MiCOM 126/127, GE Multilin F650, GE Multilin UR series, ICE NPx800, Schneider MODICON TSX Premium with special COSTRONIC software, Schneider Sepam protection relay www.areva-td.com, www.gedigitalenergy.com, www.groupeice.com, www.costronic.ch
Wago
Modbus RTU und Open Modbus TCP
The driver understands the "Modbus RTU" protocol for serial connections and TCP/IP connections and the "Open Modbus TCP" protocol for TCP/IP connections. The driver is a Modbus Master. (please use the Process Gateway as a Modbus slave)
Wago
straton / zenonLogic Treiber
Driver for the connection to straton and zenonLogic
Wago
straton NG Treiber
Driver for straton / zenonLogic connections. Replaces the straton32 driver. The driver can use several connections at the same time and uses an improved communication design.
zenon system driver
Alternative Datenpunkte
Serves to combine two or more source variables into a virtual variable. With the help of a selector variable, a decision is made which serves to combine two or more source variables into a virtual variable. With a help of a selector variable, a decision is made on which source variable is used. A controller can thus be connected via two different drivers. Depending on which driver is the better connection, it then provides values to the control system for the virtual variable.
zenon system driver
Treiber für interne Variablen
Driver for internal variable. Variables can be local or global and can be started with an initial value or the last value (remanence). The driver does not consume any I/Os or TAGs.
zenon system driver
Treiber für math. Berechnungen
zenon math driver For numeric and binary operations. The driver does not use any I/Os or TAGs.
zenon system driver
--
--
zenon system driver
Remote Runtime Treiber
Driver for read-only communication with a remote runtime system. Remote runtimes from version 5.50 are supported. No project amendment is required on the remote system.
zenon system driver
Treiber für Simulator-Variablen
zenon simulator driver for simulation and internal variables. Variables can also be stored permanently. The driver does not consume any I/Os or TAGs.
zenon system driver
Treiber für System-Variablen
zenon system driver to read internal project information, network information, PC hardware information etc. The driver does not use any I/Os or TAGs.